Wire & Cable
All Categories
The high voltage wire and cable options listed below can be customized (e.g. shielded and/or jacketed with the materials of your choice) to your specifications. Contact our engineering department for more information.
Item # |
Voltage |
No. of Conductors |
Diameter |
Gauge |
Conductor Material |
Shield |
Insulation Material |
Quantity |
---|---|---|---|---|---|---|---|---|
2232A | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.300 in | Gauge N/A 6 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Polyethylene | |
6905 | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.105 in | Gauge N/A 22 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Unshielded | Insulation Material N/A Teflon | |
2232 | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.470 in | Gauge N/A 6 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Polyethylene | |
2164 | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.505 in | Gauge N/A 11 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper | Insulation Material N/A Polyethylene | |
2167 | Voltage N/A 3 KVAC10 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.015 in | Gauge N/A 6 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper | Insulation Material N/A Polyethylene | |
2075 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.235 in | Gauge N/A 12 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2208 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.381 in | Gauge N/A 4 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2132 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.300 in | Gauge N/A 6 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2139 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.256 in | Gauge N/A 8 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2202 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.230 in | Gauge N/A 10 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2185 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.126 in | Gauge N/A 20 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2075SJ | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.420 in | Gauge N/A 12 AWG | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2168 | Voltage N/A 5 KVAC20 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.566 in | Gauge N/A 8 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper | Insulation Material N/A Polyethylene | |
2183 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 3 | Diameter N/A 0.730 in | Gauge N/A | Conductor Material N/A Silicone-insulated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2181-1 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.800 in | Gauge N/A | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2207 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.900 in | Gauge N/A | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2201 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.540 in | Gauge N/A | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2211 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.620 in | Gauge N/A | Conductor Material N/A Tin-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2217 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 4 | Diameter N/A 0.590 in | Gauge N/A | Conductor Material N/A Silver-plated Copper | Shield N/A Tin-coated Copper Braid | Insulation Material N/A Silicone Rubber | |
2249 | Voltage N/A 5 KVAC15 KVDC | No. of Conductors N/A 9 | Diameter N/A 0.538 in | Gauge N/A | Conductor Material N/A Silicone-insulated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2215 | Voltage N/A 10 KVAC30 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.275 in | Gauge N/A 16 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2178 | Voltage N/A 10 KVAC30 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.186 in | Gauge N/A 20 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A Unshielded | Insulation Material N/A Silicone Rubber | |
2157 | Voltage N/A 10 KVAC25 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.145 in | Gauge N/A 2 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper Mylar | Insulation Material N/A Polyethylene | |
2255 | Voltage N/A 10 KVAC25 KVDC | No. of Conductors N/A 1 | Diameter N/A 1.550 in | Gauge N/A 0000 AWG | Conductor Material N/A Tin-plated Copper | Shield N/A EPR | Insulation Material N/A EPR | |
2245 | Voltage N/A 10 KVAC25 KVDC | No. of Conductors N/A 1 | Diameter N/A 0.620 in | Gauge N/A 11 AWG | Conductor Material N/A Bare Copper | Shield N/A Bare Copper | Insulation Material N/A Polyethylene |